What was found
MAIN DOOR: DOOR IS BROKEN. WILL NOT CLOSE OR OPEN FULLY AND IS BINDING ON THE FUSELAGE. FOUND DOOR LOCK HANDLE OUT OF SEQUENCE AND IN THE LOCKED POSITION, CYCLED LOCK HANDLE TO THE UNLOCKED POSITION AND RAN DOOR THRU WITH THE CREW A TOTAL OF FOUR CYCLES TRYING TO GET IT TO DUPLICATE ALL ATTEMPTS TO DUPLICATE ISSUE FAILED, MED OPERATED ALL FOUR TIME THE WAY IT IS SUPPOSED TO WITH NO FURTHER DEFECT NOTED. IA W CLR 3 50 AMM CH'S 52-11-00-0L0-801 AND 52-11-00-410-801 OP'S CK GOOD.