Service difficulty report · Sensor · Cndair CL6002B16

Difficulty date
November 2, 2022
Submitted
November 3, 2022
Operation
Air carrier
Aircraft
N208QS
Make and model
Cndair CL6002B16
Aircraft serial
6056
Aircraft time
6,327 hours, 3,471 cycles
Part
Sensor
Part number
74411645
Part serial
150411
Condition
Malfunctioned
Location
Rt Overheat
Stage of operation
NR
How discovered
O
Nature of condition
J
Precautionary procedure
E

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

RIGHT JETPIPE OVHT RED CAS MESSAGE ILLUMINATED IN FLIGHT. FOLLOWED CHECKLIST WHICH HAD US SHUT THE RT ENG DOWN IN FLIGHT. CAS MESSAGE WAS STILL ILLUMINATED AFTER SHUTTING DOWN ON RAMP. REMOVED THE FAILED RT ENGINE EXHAUST NOZZLE SENSING ELEMENT. INSTALLED A NEW ELEMENT WORK DONE IAW AMM 26-11-04. REPLACED TWO DAMAGED ELEMENT CLAMPS WITH TWO NEW CLAMPS. PERFORMED AN OPS TEST OF ENGINE FIRE/OVERHEAT DETECTION SYSTEM, OPS CHECKED GOOD IAW AMM 26-11-00 AND 78-10-01.