Service difficulty report · Power Supply · Cndair CL6002B16

Difficulty date
November 17, 2022
Submitted
November 18, 2022
Operation
Air carrier
Aircraft
N252QS
Make and model
Cndair CL6002B16
Aircraft serial
6180
Aircraft time
121 hours, 72 cycles
Part
Power Supply
Part number
6013211
Part serial
26845
Condition
Inoperative
Location
Emergency Lights
Stage of operation
TX
How discovered
9
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

EMERG EXIT SIGN/LIGHT: FRONT EMERG EXIT, BOTH OVERWING EMERG LIGHTS, AND THE THREE EMERG LIGHTS ON COUCH ARE FLASHING RAPIDLY THEN COME ON STEADY FOR 20-30 SECONDS THEN GO OUT. THIS OCCURS EVERY COUPLE MINUTES. TRIED TURNING OFF AND BACK TO ARM POSITION PLUS APU SHUTDOWN TO RESET BUT NO CHANGE. ALL ELECTRICAL ON AC AND DC SYNOPTIC PAGES ARE NORMAL. SEE VIDEOS FOR EXAMPLE. //SIGNOFF // RAN APU AND DUPLICATED EMERGENCY UGHTS FLASHING IN THE ARM POSMON, REMOVED PILOT SIDE AFT WALL IN COCKPIT TO GAIN ACCESS TO POWER SUPPLY. DISCONNECTED POWER SUPPLY AND PERFORMED OPS CHECK. STILL FLASHLNG. RECONNECTED POW.ER SUPPLY AND CLOSED COCKPIT PANEL FOUND THAT WITH THE EMERGENCY LIGHT SWITCH IN THE ON POSIIION BOTIOM EMERGENCY EXIT DOOR UGHT AND AFT MOST AISLE UGHT DID NOT ILLUMINATE. REMOVED CARPET AND ACCESS PANELS IN THE AFT BAGGAGE COMPARTMENT TO GAIN ACCESS TO BOTH AFT POWER SUPPLIES. DISCONNECTED POWERSUPPUES ONE AT A TIME, WHEN AFT MOST POWER SUPPLY WAS REMOVED EMERGENCY' LIGHTS DID NOT FLICKER IN ARM POSITON. REMOVED AFT POWER SUPPLY AND REPLACED WITH SERVICEABLE UNIT, OPS CHECK GOOD. INSTALLED ALL ACCESS PANELS AND CARPETING. ALL WORK DONE IAW BOMBARDIER CH 650 AMM 33-51-0L