What was found
MAIN EXIT SIGN/LIGHT: THE EXIT SIGN UPPER RIGHT CORNER OF MAIN DOOR ALONG WITH THE LOWER RIGHT HAND SIDE ILLUMINATED RED EXIT SIGN LIGHT, AND TOE KICK LIGHT REMAINED ON AFTER SHUT DOWN. //SIGNOFF// RESET #1 EMERGENCY LIGHTING INERTIA SWJTCH (SCOOI) AND THE EXIT SIGN UPPER RIGHT CORNER OF MAIN DOOR ALONG WITH THE LOWER RIGHT HAND SIDE TLLUMJNATED RED EXIT SIGN LIGHT, AND TOE KICK LIGHT SHUTS DOWN. PERFORMED EMERGENCY LIGHT POWER SUPPLY BA TIER Y EXERCISE PROCEDURE AND FOUND #1 PACK WEAK. REMOVED AND REPLACED #1 EMERGENCY LIGHTING BATTERY PACK (UCO 19) IA W CE-680A AMM 33-50-06 AND PERFORMED EMERGENCY LIGHT ADJUSTMENT/TEST IAW CE-680A AMM 33-50-00, AND SYSTEM OPS CHECK OK, OK TO SERVICE.