What was found
EMERG EXIT SIGN/LIGHT: AFTER AIRCRAFT SHUTDOWN, INTERIOR EMERGENCY LIGHTS AROUND MAIN CABIN DOOR WILL NOT EXTINGUISH. *** CORRECTIVE ACTION *** OPS CHECKED EMERGENCY LIGHTING SYSTEM. FOUND #1 INERTIA SWITCH (SC001) ACTIVATED. RESET SWITCH, OPS CHECKED GOOD. RECHARGED BATTERY PACKS. ALL WORK ACCOMPLISHED IAW CESSNA AMM 33-50-11. COMPLETED TC-FLT-33-1001 REV 2 DATED 20OCT2022, EMERGENCY LIGHTING POWER SUPPLY BATTERY EXERCISE PROCEDURE. ALL LIGHTS AND BATTERY PACKS CHECK GOOD AFTER 10 MIN TEST. RECHARGED BATTERY PACKS IAW AMM 33-50-00