As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
LEFT HORIZONTAL STAB: AFTER EXTENDING FLAPS TO 15 FOR LANDING, WE RECEIVED A STAB MISCOMP APPROX 1 MIN AFTER THE HYD PRESS HAD BEEN CONTINUISLY ILLUMINATED. THE STAB MISCOMP EXTINGUISHED AND APPROX 1 MIN LATER THE STAB MISCOMP RETURNED A SECOND TIME PRIOR TO GEAR EXTENSION. AFTER RUNNING THE QRH AND PULLING THE STAB CONTROL CB, THE HYD PRESS EXTINGUISHED. //SIGNOFF// REMOVED AND REPLACED FAULTY AIRSPEED SWITCH WITH NEW UNIT IAW CE560XL AMM 27-40-00, LEAK AND OPS CHECK GOOD. NO FURTHER ACTION REQUIRED AT THIS TIME.