As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
EMERGENCY LIGHTING: 3 EMERGENCY AISLE PATH LIGHTS ARE OUT. THE RED ARROW LIGHTS, TWO IN ZONE 3-UNDER THE COUCH AND TABLE, ONE IN ZONE 4 UNDER SEAT 14. COULD NOT DUPLICATE CUSTOMER DISCREPENCY. PERFORMED SEVERAL OPERATIONAL TESTS OF THE EMERGENCY LIGHTS IN DIFFERENT POWER CONFIGURATIONS WITH NO DISCREPENCIES NOTED, REFERENCE GL7500 SAMP BD700-A-J33-530-00-03AAA-320A-A. NO FURTHER MAINTENANCE REQUIRED.