What was found
FLOOR EMERG EXIT LIGHT: FLOOR EMERGENCY EXIT LIGHT AT SEAT 5 IS INOPERATIVE. DOES NOT ILLUMINATE WITH THE EMERGENCY LIGHTING SYSTEM OR THE NORMAL CLARITY PATH LIGHTING SYSTEM. REPEAT WRITE UP. ARRIVED AT AIRCRAFT AND VERIFIED PILOT FINDINGS. INSPECTED LIGHT ASSY WITH NO DEFECTS. GAINED ACCESS TO THE LIGHT ASSY PLUG AND FOUND IT DISCONNECTED. RECONNECTED PLUG AND OPS CHECKED LIGHT WITH NO DEFECTS. VERIFIED LIGHT WORKED WITH PATH LIGHTING AND EMER LIGHTING WITH NO DEFECTS NOTED. REF CE 680A AMM 33-50-00