As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FLOOR EMERG EXIT LIGHT: EMERGENCY PATH LIGHTING UNDER SEAT 5 DID NOT ILLUMINATE DURING PREFLIGHT CHECK OF EMERGENCY LIGHTS. GAINED ACCESS TO SEAT #S PATH LIGHT CONNECTOR. FOUND CONNECTOR BROKEN. REPAIRED CONNECTOR WITH NJA SUPPLIED NEW MOLEX CONNECTOR P/N: 43020-0401, AND NEW PIN P/N: 43031-0009. OPS CHECKED GOOD. NO FURTHER DISCREPANCIES NOTED. REF: CE-680A SPM 20-30-00.