What was found
MAIN CABIN DOOR EMER EXIT SIGN LIGHT INOP. EMERG EXIT SIGN ON FWD CABIN BULKHEAD WILL NOT ILLUMINATE. POWERED ACFT & DUPLICATED DISCREPANCY. INSPECTED LIGHT FOR DEFECTS. PERFORMED RESEARCH OF EMER LIGHTING SYS. GAINED ACCESS TO FWD EMER LIGHT & EXTERIOR EMER LIGHT POWER SUPPLIES. SWAPPED POWER SUPPLIES, ISSUE DID NOT FOLLOW. WIRING CHECKED AT CONNECTORS P6116 & P3LF, WIRING CHECKED GOOD. INSPECTION, FOUND 2 PINS "A" & "B" FOR CONNECTOR THAT POWERS EXIT SIGN, PINNED INCORRECTLY. REPINNED CONNECTOR. FOUND 2 PINS FOR CONNECTOR THAT POWERS LT FWD BULKHEAD EXIT SIGN PINNED INCORRECTLY, REPINNED CONNECTOR. OPS TESTED EMERGENCY LIGHTS, OPS CHECKED GOOD IAW AMM 33-51-00-710-801.