Service difficulty report · Door · Emb EMB505

Difficulty date
June 18, 2024
Submitted
June 19, 2024
Operation
Air carrier
Aircraft
N426QS
Make and model
Emb EMB505
Aircraft serial
50500483
Aircraft time
5,335 hours, 4,104 cycles
Part
Door
Condition
Leaking
Location
Emergency Exit
Stage of operation
NR
How discovered
O
Nature of condition
E
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

HIGH FREQUENCY VIBRATION & NOISE FROM RT OF FUSELAGE. EMERGENCY EXIT HANDLE RATTLES & EXIT DOOR NOISE. INSPECTED LATERAL SEAL FOUND LIFTNG ON BOTH LT & RT OF ACFT, APPLIED RTV ALONG LENGTH OF SEAL FROM AFT WING ROOF TO T/E WHERE FLAP SEAL STARTS. INSPECTED RT FUSELAGE FOR ANY ABNORMAUTIES THAT COULD CAUSE A HIGH FREQUENCY VLBRATION, FOUND BATTERY DOOR LOOSE & WOULD RATTLE WHEN WHEN TAPPED ON, INSPECTED HINGE & LATCHES. FOUND LOWER AFT LATCH WORN ON STRIKER PLATE. REMOVED EMERGENCY EXIT & REMOVED TRIM TO INSPECT ALL LATCHES & LOCKING MECIIANISMS. ON INSP, NOTED SPRINGS & HANDLE HINGE CHEAKY & DRY, CLEANED & LUBED PIVOT POINTS, HANDLE OPS CHECKS GOOD IAW AMM 52-20-20; 53-04-31.

More about the Emb EMB-505