What was found
BLEED 2 FAIL YELLOW CAS: UPON LANDING IN TORRANCE, SLIGHT BURNING SMELL IN THE COCKPIT, BLEED 2 FAIL YELLOW CAS MESSAGE APPEARED, YELLOW X OVER THE PRSOV NUMBER 2 ON SYNOPTIC. BLEED 2 OFF WHITE CAS ILLUMINATED. PERFORMED WIRING CHECKS BETWEEN AMS CONTROLLER AND THE FOLLOWING COMPONENTS: PRSOV 2, FAV 2 AND TEMP SENSORS. CONTINUITY CHECKS ARC GOOD. R&R THE PRSOV 2 DUE TO BLEED 2 FAIL CAS MESSAGE. OPERATIONAL CHECK IS GOOD. WORK DONE IAW PHENOM 300 AMM CH. 36-11-01. NO DEFECTS NOTED.