What was found
CABIN EMERG LIGHT: EMERGENCY EXIT SIGN OVER SEAT 7 DOES NOT ILLUMINATE WITH AIRCRAFT POWER OFF AND SWITCH IN ARM POSITION CORRECTIVE ACTION: BENCH CHECKED AFT CABIN EMER LIGHT WITH 28VDC POWER SOURCE, LIGHT ASSEMBLY IS OPERATIONAL. REPLACED THE DAMAGED MOLEX PINS P/N: S2216-3 ON THE LIGHT ASSEMBLY CONNECTOR. REINSTALLED ORLGINAL AFT EMERGENCY LIGHT ASSEMBLY P/N: 9919054-1, S/N: 23D378, OPERATIONAL CHECK OF THE EMERGENCY LIGHT SYSTEM JS GOOD. WORK COMPLETED LN REF WITH CE·680A AMM 33-50-00.