Service difficulty report · Sensing Element · Bombdr BD1001A10

Difficulty date
October 12, 2024
Submitted
October 15, 2024
Operation
Air carrier
Aircraft
N754QS
Make and model
Bombdr BD1001A10
Aircraft serial
20732
Aircraft time
7,166 hours, 4,157 cycles
Part
Sensing Element
Part number
0431102111A
Condition
Defective
Location
Overheat Loop
Stage of operation
CL
How discovered
O
Nature of condition
N
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

BLEED AIR: 13 MINUTES AFTER TAKE OFF APOX 32000 FT RED LEFT BLEED LEAK MASTER WARNING ILLUMINATED ALONG WITH RED EICAS. RAN QRH PROCEDURE WARNING WENT AWAY. RETURED TO KLAS B3-007016 CORRECTIVE ACTION: COMPLIED WITH REMOVAL OF LH BLEED LOOP SENSING ELEMENT DUE TO RED LEFT BLEED LEAK MASTER WARNING ILLUMINATED AND INSTALLATION OF A NEW LH BLEED LOOP SENSING ELEMENT IAW CL 350 AMM 36-21-01-400-801. NO FURTHER DEFECTS NOTED. OPS CHECK GOOD.