As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
RH EXTERIOR EMERGENCY LIGHT DOES NOT ILLUMINATE. THE QRH PROCEDURE FOR CHARGING THE EMERGENCY BATTERY PACKS WAS FOLLOWED, AND LIGHTS WILL STILL NOT ILLUMINATE. PERFORMED THE EMERGENCY LIGHTING - ADJUSTMENT/TEST. RESET EMER LIGHT BATTERY PACKS 2-3-4. PERFORMED OPS CHECK SUCCESSFULLY, NO FUTHER DEFECTS NOTED. RETURNED AIRCRAFT TO ORIGNAL CONFIG. ALL WORK IAW AMM 33-50-00.