Service difficulty report · Actuator · Bombdr BD7001A11

Difficulty date
February 24, 2025
Submitted
February 28, 2025
Operation
Air carrier
Aircraft
N115QS
Make and model
Bombdr BD7001A11
Aircraft serial
9734
Aircraft time
7,786 hours, 3,534 cycles
Part
Actuator
Part number
GS32105919
Part serial
F0328
Condition
Faulty
Location
Zone 800
Stage of operation
IN
How discovered
V
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

MAIN DOOR MOTOR: MAIN CABIN DOOR MOTOR INTERMITTENTLY CUTS OUT WHEN CLOSING THE DOOR USING THE INTERIOR CONTROLS. ALSO, DURING DOOR CLOSING, WHEN THE DOOR REACHES THE TOP THE MOTOR SOMETIMTES CUTS OUT AND DOOR FALLS IMMEDIATELY TO THE OPEN POSITION OR THE DOOR HOLDS AT THE TOP POSITION FOR A OF COUPLE SECONDS BUT THE MOTOR MAKES A STRAINED SOUND. CORRECTIVE ACTION; REMOVED FAULTY PASSENGER DOOR ACTUATOR AND REPLACED WITH A REPAIRED UNIT REF GLOBAL 5000 AMM / 52-11-25. TECHS VERIFIED THE RIGGING OF THE DOOR ACTUATOR PRIOR TO INSTALL. PERFORMED OPERATIONAL CHECKS VERIFIED RIGGING REF GLOBAL 5000 AMM 52-11-25. PERFORMED SATISFACTORY FUNCTIONAL CHECK REF GLOBAL 5000 AMM 52-11-00.