Service difficulty report · Drain · Emb EMB505

Difficulty date
March 20, 2025
Submitted
March 24, 2025
Operation
Air carrier
Aircraft
N360QS
Make and model
Emb EMB505
Aircraft serial
50500254
Aircraft time
8,466 hours, 6,620 cycles
Part
Drain
Part number
140N2022S1
Condition
Defective
Location
Zone 100
Stage of operation
CL
How discovered
O
Nature of condition
E
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FUSELAGE DRAIN: BETWEEN 12000 AND 16000, WE EXPERIENCED A SUDDEN ONSET VIBRATION SEEMINGLY ORIGINATING FROM THE FLOOR AREA NEAR THE COCKPIT. WE COULD HEAR A LOUD VIBRATION AS WELL. IT DISSIPATED AS WE CLIMBED ABOVE 16,000. IT MAY NOT BE AUDIBLE IN ATTACHED VIDEO, BUT WE INCLUDED TWO VIDEOS (1ST WITH VIBRATION, 2ND AFTER IT STOPPED.) DISCUSSED IN FLIGHT WITH MAINTENANCE CONTROLLER WHO SUGGESTED POTENTIAL PRESSURIZATION DRAIN ISSUE AND AOG. CORRECTIVE ACTION; REMOVED AND REPLACED 2 EACH FUSELAGE DRAINS, ONE HAD A WEEK SPRING AND OTHER WAS CRACKED UPON REMOVAL ALL WORK ACCOMPLISHED IAW PHENOM 300 AMM 53-05-00