What was found
MAIN DOOR HARDWARE: THE MAIN ENTRY DOOR LIFT ARM IS NO LONGER ATTACHED, THE SCREW HOLDING THE UPPER AND LOWER LIFT ACTUATOR ARMS TOGETHER HAS BACKED OUT COMPLETELY. THE SCREW AND TWO NYLON WASHER HAVE BEEN RECOVERED FROM THE RAMP. CORRECTIVE ACTION: DUE TO LIFT ARM SCREW NO LONGER BEING ATTACHED. RECOVERED AND INSTALLED SCREW AND NYLON WASHERS. INSTALLED CUSTOMER SUPPLIED RETAINING RING P/N:MS16625-4031 ALL WORK DONE IN REF WITH CE-680A AMM 52-15-15 OPERATIONAL CHECK GOOD NO DEFECTS NOTED.