Service difficulty report · Battery Pack · Emb EMB505

Difficulty date
July 11, 2025
Submitted
July 14, 2025
Operation
Air carrier
Aircraft
N312QS
Make and model
Emb EMB505
Aircraft serial
50500153
Aircraft time
10,157 hours, 8,052 cycles
Part
Battery Pack
Condition
Faulted
Location
Zone 200
Stage of operation
CR
How discovered
O
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DURING FLT, EMERGENCY LIGHTS REMAINED ILLUMINATED & DID NOT TURN OFF AS EXPECTED. VERIFIED SWITCH POSITION & CYCLED THE EMERGENCY LIGHT SWITCH. LIGHT REMAINED ON THROUGHOUT DURATION OF FLT. APPLIED POWER WITH A GPU. OPS THE EMERGENCY LIGHTS SWITCH NOTING THAT EMERGENCY LIGHTS WOULD ILLUMINATE IN BOTH THE ARMED & ON POSITIONS. GAINED ACCESS TO #1 & #2 EMERGENCY BATTERIES AS REQUIRED. PERFORMED GVI OF BOTH BATTERIES WITH NO OBVIOUS DEFECTS. PERFORMED OPS CHECK OF EMERGENCY LIGHTS IAW MM 33-52-00, NOTING LIGHTS WOULD STAY ON IN THE ARM POSITION. PER FIM TASK 33-50-00-810-801-A, TECHS NOTED THAT WITH ONLY #1 BATTERY CONNECTED, SYSTEM WOULD OPS AS REQUIRED . WHEN ONLY THE #2 BATTERY IS CONNECTED, THE EMERGENCY LIGHTS WOULD STAY ILLUMINATED IN THE ARM POSITION, PER FIM TASK 33-50-00-810-801-A, #2 BATTERY IS FOUND TO BE FAULTY. REMOVED FAULTY #1 BATTERY & INSTALLED REPAIRED BATTERY PER MM 33-52-01. REMOVED FAULTY #2 BATTERY & INSTALLED REPAIRED BATTERY PER MM 33-52-01. PERFORMED THE OPS TEST OF EMERGENCY LIGHTS IAW MM 33-52-01, NO DEFECTS NOTED.

More about the Emb EMB-505