What was found
MAIN DOOR HANDLE HARD TO OPERATE GETS STUCK AND NEEDS TO BE MUSCLED UP TO OPEN COMPLIED WITH OPS CHECKS TO DUPLICATE DISCREPANCY. FOUND FWD UPPER PIN WAS UNLIKE THE OTHER AND HAD EVIDENCE OF FREE PLAY WHEN ATTEMPTING TO FORCE PIN INTO RECEPTACLE. VISUAL INSPECTIONS FOUND NO GREASE OR LUBE PRESENT. VISUAL INSPECTING ALL MOVING PARTS, ATTACHING HARDWARE FOR PIN LOCK MECH HAD TENSION. THIS NOT ALLOWING THE DOOR PIN TO EXTEND OR RETRACT. COMPLIED WITH R & R OF BOLT & BUSHING FOR DOOR PIN MECHANISM, NO TENSION PRESENT ON ATTACHING HARDWARE & DOOR MECHANISMS. LUBED ALL COMPONENTS, COMPLIED WITH DOOR ADJUST TEST. NO DEFECTS NOTED. ALL WORK DONE IAW AMM 12-2-40, 52-10-04, & 52-10-07. OPS CHKD GOOD