Service difficulty report · Apu · Cndair CL6002B16

Difficulty date
December 10, 2025
Submitted
December 15, 2025
Operation
Air carrier
Aircraft
N235QS
Make and model
Cndair CL6002B16
Aircraft serial
6125
Aircraft time
6,076 hours, 3,434 cycles
Part
Apu
Condition
Leaking
Location
Zone 100
Component
Apu · Hnywl
Component part number
38006041
Stage of operation
TX
How discovered
O
Nature of condition
B
Precautionary procedure
D

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AFTER TURNING ON THE APU AND AIR-CONDITIONING, PACS, STRONG OIL/SMOKE ODOR FROM AIR-CONDITIONING. NOTICED IN COCKPIT. PERFORMED A BOROSCOPE INSPECTION. PERFORM OPS CHECK OF A/C SYS WITH APU BLEED & VERIFIED OIL ODOR IN COCKPIT. PERFORMED BOROSCOPE INPECTION OF APU NOSE CONE. APU MUST BE REPLACED DUE TO REPEAT WRITE UP. REMOVED APU AND INSTALLED INSPECTED APU, SERVICED WITH 3QT APU AND STARTER GEN IAW 0MM 12-13-49. ALL LEAKS & OPS CHKD GOOD. NO DEFECTS. WORK COMPLETED IAW AMM 49-10-00. PERFORMED A FINAL OPS CHECK OF APU. & AIRCONDITIONING SYS IAW 49-50-00. CHECKED GOOD. NO OIL, ODOR/SMOKE IN COCKPIT.