What was found
AFTER TAKE OFF, SELECTED FLAP HANDLE TO 0 DEGREE, FLAP FAIL CAS MESSAGE CAME ON. CONFIRMED FLAPS WERE STILL 20 DEGREES. ACCOMPLISHED FLAP FAILS CHECKLIST & RETURNED TO BED. FOUND FLAPS AT 20 DEG & HANDLE AT 0 DEG. INTERROGATED CMC & UNDER SERVICE MESSAGE HISTORY FOUND A FLAP MOTOR 2 OVERHEAT POST WITH TODAYS DATE. PERFORMED FLAP RESET AND. PERFORMED SEVERAL OPS CHECKS, ALL NORMAL. PER CRC PERFORMED STEPS IN FLAPS FAIL TROUBLE SHOOTING GUIDE USING NOTED MM REFRENCES AND FOUND NO DEFECTS. R & R WITH REPALRED LT & RT BDU UNITS IAW AMM 27-51-07. OPS CHECKED GOOD.