What was found
STRONG ODOR OF FUMES ON DEPARTURE WITH TAKEOFF POWER. PER EMB CC ACCOMPLISH FIM TASK 21-20-00-810-801-A. C/W EMB-505 FIM TASK 21-20-00-810-801-A WITH NFF C/W HIGH POWER RUNS AND COULD NOT DUPLICATE THE SQK. PER MOC REQUEST POWERED ON ALL GALLEY/CABIN IFE EQUIP, PORTABLE MONITORS AND CABIN LIGHTING FOR A PERIOD OF 1 HR WITH NFF. CHECKED ALL PFD AND MFD AVIONICS COOLINGS FANS WITH NO SMELLS OR DEFECTS NOTED AT THIS TIME.