Service difficulty report · Sensor · Bombdr BD7001A12

Difficulty date
February 8, 2026
Submitted
February 11, 2026
Operation
Air carrier
Aircraft
N190QS
Make and model
Bombdr BD7001A12
Aircraft serial
70196
Aircraft time
1,077 hours, 371 cycles
Part
Sensor
Part number
93574A010005
Part serial
93574EB02413
Condition
Defective
Stage of operation
CL
How discovered
O
Nature of condition
B
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

ABOUT 5 MINUTES INTO FLIGHT, NOTICED A SLIGHT SMOKY ODOR & A MIN LATER, FA SAID SHE SMELLED SMOKE. SIC ALSO SMELLED SMOKE. WAS A STRONGER TOWARDS ZONE 3 & IT WENT AWAY & CAME BACK. SMELLED LIKE A CAMP FIRE SMOKE, BUT FA SAID IT SMELLED LIKE A CHEMICAL. NOT A STRONG ODOR & NEVER WENT TOTALLY AWAY. RAN A/C SYSTEM ON APU BLEED AIR WITH MAXIMUM HEAT SELECTED IN AUTO MODE, NO UNUSUAL ODORS NOTED. RAN SYSTEM IN MANUAL INCREASING TEMP SIGNIFICANTLY BUT STILL HAD NO ODOR. PERFORMED A HIGH-POWER RUN WITH TEMP MAXED IN AUTO & NO ODOR. RETURNED TO RAMP & SHUTDOWN ENGS, LEFT APU RUNNING WITH TEMP IN MAX AUTO. BEFORE SHUTTING APU DOWN, LOOKED AT BLEED SYNOPTIC PAGE & NOTICED ENTRY DUCT TEMP WAS 70 DEGREES C. PERFORMED TRIM AIR VALVE OPS CHK, & DUCT TEMP SENSOR OPS CHK, NO DEFECTS NOTED. TOOK ACFT OUT FOR ANOTHER HIGH-POWER RUN WITH NO DEFECTS. COULD NOT DUPLICATE HIGH TEMP IN ENTRY DUCT OR ODOR. REPLACED ENTRY DUCT TEMP SENSOR E105. REMOVED THE SUSPECTED BAD DUCT TEMP SENSOR E105 & INSTALLED A NEW TEMP SENSOR E105 & OPS CHKD GOOD IAW AMP TASKS BD700-A-J21-21-21-00AAA-520A-A & BD700-A-J21-21-21-00AAA-720A-A .