Service difficulty report · Control Lever · Emb EMB505

Difficulty date
March 15, 2026
Submitted
March 19, 2026
Operation
Air carrier
Aircraft
N499QS
Make and model
Emb EMB505
Aircraft serial
50500918
Aircraft time
106 hours, 84 cycles
Part
Control Lever
Part number
7805019
Part serial
3397
Condition
Defective
Stage of operation
AP
How discovered
O
Nature of condition
F
Precautionary procedure
L

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

ON APPROACH ATC ASKED FOR SLOWEST PRACTICAL SPEED. CREW STARTED TO CONFIGURE BY LOWERING FLAPS AND GEAR. FLAPS 2 WAS REQUESTED AND AN AMBER FLAP FAIL CAS WAS DISPLAYED. CREW DECLARED AN EMERGENCY AND CANCELLED APPROACH CLEARANCE. FLAP FAIL QRC WAS ACCOMPLISHED AND WERE ABLE TO MOVE THE FLAPS TO ZERO AND THEN FULL ON THE SECOND CYCLE AND THE FLAP FAIL CAS EXTINGUISHED AND A NORMAL LANDING WAS ACCOMPLISHED. MX CONTROL REQUESTED TO AOG THE AIRPLANE. CORRECTIVE ACTION: REPLACED FLAP SELECTION LEVER. OPS CHECK GOOD. AMM 27-53-01-400-801-A

More about the Emb EMB-505