What was found
CABIN PREP TEAM REPORTS THE EMER LIGHTS ON N554QS ARE STUCK ON AND WILL NOT SHUT OFF. ACCESSED INERTIAL SWITCH IN COCKPIT CENTER PEDESTAL, PERFORMED RESET / PROCEDURE AND VERIFIED LIGHTS EXTINGUISHED, RAN APU FOR ABOUT 30 TO 45 MINUTES TO PROPERLY CHARGE LIGHTS DUE TIME PERIOD BEING ON IAW AMM 33-50-00. CHECKED GOOD. NO DEFECTS NOTED