What was found
EMERGENCY EXIT SIGN LIGHT INOP ABOVE MAIN CABIN DOOR CORRECTIVE ACTION: FOUND THE EMERGENCY EXIT LIGHT CONNECTOR WAS NOT FULLY SEATED ON ITS RECIPROCAL, WHEN TECHS ATTEMPTED TO RESEAT THE CONNECTOR WE NOTED IT WAS PREVIOUSLY INSTALLED 180 DEGREES / OUT. TECHS RECONNECTED THE LIGHTING CONNECTOR IN THE PROPER ORIENTATION AND PERFORMED MULTIPLE OPS CHECKS PER PHENOM 300 AMM 33-52-00. ALL OPERATIONAL CHECKS WERE GOOD EACH TIME, NO FURTHER DEFECTS ARE NOTED AT THIS TIME.