What was found
DURING DECENT THROUGH FL350 RT MAIN DOWN & LOCKED INDICATOR ILLUMINATED. UNLOCK INDICATOR REMAINED EXTINGUISHED. DESCENDING THROUGH 8000 FT RT MAIN INDICATOR EXTINGUISHED. GEAR EXTENDED NORMAL ON APPROACH. LIFTED ACFT, SWUNG GEARS, NO DEFECTS NOTED. RT GREEN LIGHT DOES NOT COME ON WHEN GEAR IS UP & LOCKED. OPS CHKD A FEW MORE TIMES, STILL NOT FAILING. COMPLETED WIRING CHK OF RT DOWN LOCK SWITCH, NO DEFECT NOTED. . REMOVED FAILED RT MLG DOWN LOCK SWITCH. REMOVED MLG CONTROL NR 1 PCB FOR MX CONVENIENCE & INSTALLED A SERVICEABLE PART. REMOVED MLG CONTROL NR 2 PCB FOR MX CONVENIENCE & INSTALLED SERVICEABLE PART. OPS CHECKED GOOD. NO FURTHER DISCREPANCIES NOTED. APPLIED SEALANT, IAW AMM 32-30-40, & 24-60-10.