What was found
FOUND DENT NEAR NOSE JACK PAD, FWD PRESSURE BULKHEAD AREA. ACCOMPLISHED NDT EDDY CURRENT & ULTRASONIC INSPECTION AT LT LOWER FORWARD PRESSURE BULKHEAD AREA AROUND JACK POINT FOR CRACKS & TO VERIFY REMAINING THICKNESS. NO CRACKS NOTED IN THE AREA OF INSPECTION. MINIMUM REMAINING THINKNESS IN AREA IS .030"-.031", NORMAL THICKNESS IS .032". COLD WORKED DEFORMED AREA TO BEST MATCH SURROUNDING FUSELAGE STRUCTURE AT NOSE JACK PAD REF AQRD ERO-575609.