What was found
DURING THE STRUCTURAL INSPECTION IT WAS FOUND AT FORWARD FUSELAGE BETWEEN FR09 AND FR11, BETWEEN STRG-11L AND STRG-13L WITH DENT, THE DAMAGE WAS REPAIRED INSTALLING REPAIR DOUBLER AS PER E.O. # COO-EO-2021-14069 R00 - WOA1K276 ÍTEM 21-4, ETD2021-190-034419 AND APPROVED ON ANAC FORM F-200 PROVIDED BY EMB.