What was found
DURING THE STRUCTURAL INSPECTION PER WORK CARD Nº: 572179-01-1-001, IT WAS FOUND AT LH WING, TOP SKIN LOWER SURFACE AT RIB 15 OVERHANG AREA WITH CORROSION. DUE TO THERE IS NOT SRM AVAILABLE TO PERFORM PERMANENT REPAIR, AIRBUS WAS CONTACTED REQUESTING REPAIR INSTRUCTIONS AND FINAL APPROVAL, UNDER AIRBUS DOSSIER 81187500 AND COOPESA JOB A1N0011 ITEM 5-24