What was found
DURING THE INSPECTION ACCOMPLISHMENT PER ALLEGIANT WORK CARD Nº: ZL-575-01-1-001 IT WAS FOUND THE RIBLET E CORRODED. DUE TO THIS FACT IT WILL BE REPLACED BY NEW ONE, DUE TO FLY BY WIRE CABLES PASS THROUGH THE MENTIONED RIBLET E AND A HOLE COMMON TO THE REBLET E WAS FOUND ELONGATED, DETAILS, WERE SENT TO AIRBUS ASKING FOR REPAIR INSTRUCTIONS AND FINAL APPROVAL, UNDER AIRBUS DOSSIER 81065802