What was found
DURING THE STRUCTURAL INSPECTION PER WORK CARD Nº: 553006-01-2-001 MPD, IT WAS FOUND AT EMPENNAGE RUDDER HINGE#4 BEARING WITH PLAY.
REPLACED FORK AND END FITTING AT HINGE ARM BR4 IAW A319-SRM TASK 55-36-42-300-008.
SEE COOPESA WORK ORDER A1M116 3-15