What was found
DESCRIPTION: DURING THE STRUCTURAL INSPECTION PER WORK CARD Nº: 553006-01-2-001 MPD, IT WAS FOUND AT EMPENNAGE RUDDER HINGE ARM#7 WITH CORROSION.
CORRECTIVE ACTION: REPLACED HINGE ARM BR7 IAW A319-SRM TASK 55-36-42-300-003. SEE COOPESA WORK ORDER A1M116 3-6