What was found
DURING THE STRUCTURAL INSPECTION PER ALLEGIANT WORK CARD Nº: 553005-01-1-001_P1-OP-UP/003, IT WAS FOUND THE EMPENNAGE, RUDDER HINGE ARM N° 1 P/N D5537131620054 AND HINGE ARM N° 7 P/N D5537131720400 OUT LIMITS, DUE THIS FACT THE PARTS MUST BE REPLACED. SEE COOPESA JOB A1N011 ITEM 3-31