What was found
PLEASE NOTE THAT DURING THE STRUCTURAL INSPECTION PER ALLEGIANT WORK CARD Nº: 531135-01-2-001 MPD, IT WAS FOUND RH WINDSHIELD SIDE POST UPPER AND FITTING P/N: D5311086520303 ATTACHMENT AT FRAME 4 (1 HOLE WITH CRACK INDICATION) CORRECTIVE ACTION: DAMAGE REPORT WAS SENT TO AIRBUS, AND THE REPAIR INTRUCTIONS WERE HANDLED UNDER AIRBUS DOSSIER 81176882 AND COOPESA JOB A1N004, NRI 2-27 AND NRI 2-36