As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING INSP, TECH FOUND CRACKED TEE ANGLE P/N 76201-23014-138 AFT SECTION. REMOVED TEE ANGLE FOUND THE ENTIRE ANGLE CRACKED AND THE FWD BATHTUB FITTING P/N 76209-03002-119 CRACKED AT THE MOUNT BOLT HOLE. THE FOLLOWING PARTS WERE REPLACED IAW SRM SA 4047-76-12: TEE FITTING P/N 76201-23014-138 LT FWD BATHTUB FITTING P/N 76209-03002-119 LT AFT BATHTUB FITTING P/N 76209-03002-125.