What was found
EBBR - IN FLIGHT, L1 WINDOW HEAT SENSOR GAVE AN OVERHEAT ODOR, SYSTEM WAS TURNED OFF. FOUND BOLT AT LOWER LEFT CORNER OF L1 WINDOW FOR ELECTRICAL CONNECTOR BURNED AND LOOSE. REPLACED BOLT AND TIGHTENED. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
EBBR - IN FLIGHT, L1 WINDOW HEAT SENSOR GAVE AN OVERHEAT ODOR, SYSTEM WAS TURNED OFF. FOUND BOLT AT LOWER LEFT CORNER OF L1 WINDOW FOR ELECTRICAL CONNECTOR BURNED AND LOOSE. REPLACED BOLT AND TIGHTENED. (M)