What was found
DURING C-6 CHECK, INSPECTION REPORTED INTERCOSTAL AT STR. 26-R BETWEEN STA.747-767 CORRODED. FABRICATED AND INSTALLED REPLACEMENT INTERCOSTAL PER DRAWING 69-16500, ITEM 4, AND SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C-6 CHECK, INSPECTION REPORTED INTERCOSTAL AT STR. 26-R BETWEEN STA.747-767 CORRODED. FABRICATED AND INSTALLED REPLACEMENT INTERCOSTAL PER DRAWING 69-16500, ITEM 4, AND SRM 51-40-02.