What was found
FA'S REPORTED A MUSTY ODOR IN FRONT OF CABIN. NO ODOR IN COCK PIT. PERFORMED TSM 05-50-00-810-831-A, INSPECTED THE PACK 1 DUCTS, OZONE FILTER CONDENSER IAW TSM 21-00-00-615-004-A NO DEFECTS NOTED. PERFORMED CLEANING BY RISIDUAL BURN IAW TSM 21-00-00-615-004-A. FOUND FWD GALLEY SUSPECT FOR PRODUCING MUSTY ODOR, CLEANED FWD GALLEY GARBAGE CONTAINERS AND COFFEE POT IAW AMM 12-21-12. NO ODOR NOTED. AIRCRAFT RELEASED BACK TO SERVICE.