What was found
DISCREPANCY: REFERENCE AIRBORNE /PEMCO N/R 12452.0220. AIRCRAFT WAS NOT GROUNDED AND IS IN CHECK FOR SCHEDULED MX. RH AFT SHEAR PLATE CORRODED CORRECTIVE ACTION: REMOVED AND REPLACED RH AFT SHEAR PLATE WITH NEW P/N D5347112420300 IAW A320 NEO SRM 51-44-11, 51-72-11-911-001, 51-11-00, 51-42-11. DISPLACED & RESECURE VAC GEN WIRE IAW A320 AMM 38-31-36-400-001-A. PERFORMED OPS TEST OF THE TOILET UNIT IAW A320 AMM 38-31-00-710-009-A. OPS TEST GOOD. NO FURTHER ACTION REQUIRED. MX ACTION IS ACCEPTABLE.//END/