What was found
DURING HEAVY CHECK EPSU TEST FAILED DUE TO POSITION 10WL UNIT FAILURE. REMOVED AND REPLACED EPSU UNIT AT POSITION 10WL IN REF TO AMM 33-51-38-000/400-001-A. EPSU SYSTEM TEST OK./END/