What was found
DEN - DURING C-CHECK, INSPECTION REPORTED .1250 INCH CRACK IN LT FUSELAGE SKIN PANEL AT BS 727, STR 16L. MAINTENANCE FABRICATED FILLER AND DOUBLER AND INSTALLED USING REQUIRED FASTENERS PER SRM 53-30-3. CYCLES: 25,993. (X)