Service difficulty report · Motor · Bell 407

Difficulty date
May 17, 2021
Submitted
May 19, 2021
Operation
General aviation
Aircraft
N803DS
Make and model
Bell 407
Aircraft serial
53880
Part
Motor
Part number
ES6106410
Condition
Overheated
Location
Blower
Part time
5 hours
Stage of operation
TO
How discovered
O
Nature of condition
M, B
Precautionary procedure
C

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

THE PILOT REPORTED A BURNING RESIN ARDOR IN THE COCKPIT AND A SPONTANEOUS FAILURE OF THE AIR CONDITIONING. THE PILOT REPORTS THAT HE HAD JUST PICKED THE AIRCRAFT UP INTO A HOVER AND WAS PREPARING TO DEPART BASE WHEN THE FAILURE OF THE AIR CONDITIONING OCCURRED. THE PILOT LANDED THE AIRCRAFT AND PERFORMED A NORMAL SHUT DOWN. MAINTENANCE WAS ADVISED AND THE AIRCRAFT INSPECTED, THE CAUSE WAS QUICKLY ISOLATED TO THE FORWARD LEFT SIDE EVAPORATOR BLOWER MOTOR WHICH WAS WARM TO THE TOUCH. THE MOTOR WAS REMOVED AND FOUND TO BE SEIZED. THE MOTOR HAD RECENTLY BEEN REPLACED AND HAD ONLY 5.4 HOURS SINCE INSTALLATION. EVAPORATOR BLOWER CIRCUIT BREAKER TRIPPED AND CAUSED AIR CONDITIONING SYSTEM TO EFFECTIVELY BECOME INOPERATIVE. THIS TYPE OF MOTOR HAS HAD A LOW FAIL RATE. CAUSE NOT KNOWN. MOTOR REPLACED

More about the Bell 407