What was found
S26L HAS MINOR DAMAGE ON FREE FLANGE BETWEEN STA 510 AND 560. REMOVED DAMAGED SECTION OF STR IAW SRM 53-00-03, REPAIR NR 2. FABRICATED 2 STRINGER SPLICES. FABRICATED 3 SHIMS IAW SRM 53-00-03. TREATED AND PRIMED STRINGER SPLICES, SHIMS AND STRINGER CLIP IAW SRM 51-20-01. INSTALLED SPLICES, SHIMS AND STRINGER CLIP IAW SRM 51-40-02. REPAIR ACCEPTED IAW EAR 67597370071.