What was found
FWD CARGO BAY BS 760, STR -24L FRAME UPPER J-ANGLE DENTED. REPAIRED FRAME STA 760, STR -24L IAW SRM 53-00-07, 51-40-02. NOTE: SUBSEQUENCT INSPECTIONS ARE REQUIRED IAW SRM 53-00-07, PAGE 208, REPAIR 5, DETAIL III AND PAGE 210, TABLE II . THIS IS A CLASS "B" REPAIR WITH FOLLOW UP INSPECTIONS REQUIRED . HFEC AND DETAILED INSPECTION REQUIRED EVERY 12,000 FLIGHT CYCLES REF 53-00-01, FIG 201, SHEET 10 OF 15, TABLE II. (SEE SDR 08-4638 FOR CORRECT REPAIR INFORMATION).