As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
E&E DOOR DENTED & HAS GOUGE MARKS AT LH EDGE OF DOOR EXTERIOR SKIN. DENTS FOUND TO BE OUT OF LIMITS BY MECHANICAL MEANS IAW SRM 52-100-2. CUT OUT DAMAGE (DIMS: 2 1/8 X 1 1/8) IAW SRM 52-00-3 FIG 1. FABRICATED DOUBLER AND FILLER REPAIR IAW SRM 52-00-3 FIG AND 52-40-1 FIG 2. TREATED AND PRIME REPAIR PARTS IAW SRM 51-10-2 AND INSTALLED PARTS IAW SRM 51-30-2.