What was found
L-2 DOOR TOP DOOR STOP HOUSING AFT SIDE HAS WORN SPOT FROM CHAFING. BLENDED L2 DOOR TOP STOP FITTING, AFT SIDE, FOUND TO BE OUT OF LIMITS IAW SRM 52-10-02 FIG 101 DET. XI. REMOVED DOOR STOP FTG IAW SRM 51-40-02. FABRICATED NEW DOOR STOP FITTING. INSTALLED NEW DOOR STOP FITTING IAW SRM 51-40-02. THIS REPAIR IS CATEGORY "A" MAJOR REPAIR.