What was found
ON CLIMB-OUT OF MEM RCVD LVL 3"MANF 2 FAIL" COMPLIED WITH QRH AND RETURNED MEM. RELEASED FOR SERVICE PER MEL/CDL: 36-23-01-02. NR 2 MANIFOLD FAIL DETECTION LOOP, INOP. MX MUST CLEAR ALERT PRIOR TO EACH DISPATCH. DO NOT PRESSURIZE PNEUMATIC SYS NR 2 EXCEPT FOR ENG START. DECAY TEST PASSED PER MM 36-00-01-5. FOUND LOOP D1-28 (C) AT FAULT. REMOVED AND INSTALLED NEW LOOP PER AMM 36-23-02-4. FOUND LOOP D1-28 (C) (UPPER SECTION) AT FAULT. REMOVED AND INSTALLED NEW LOOP IAW AMM 36-23-02-4, TESTED IAW MM 36-23-01 AND MM 36-23-00. CKS GOOD. CLOSED ALL ACCESS PANELS ON VERTICAL STAB.