What was found
FWD PIT, CORROSION ON OTBD SIDE OF VERTICAL STIFFENER AT BS 740, BETWEEN STRINGERS 26L AND 25L. REMOVED AND REPLACED DAMAGED CHORD WITH NEW PART IAW DWG 65-15940, SRM 51-30-5 AND SRM 51-30-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD PIT, CORROSION ON OTBD SIDE OF VERTICAL STIFFENER AT BS 740, BETWEEN STRINGERS 26L AND 25L. REMOVED AND REPLACED DAMAGED CHORD WITH NEW PART IAW DWG 65-15940, SRM 51-30-5 AND SRM 51-30-2.